tqc - Search results :.  Site Info   Whois   Traceroute   RBL Check  

Enter Web Site URL Address:
 

Tqc: 225 results found.

bresle-kit.com BRESLE KIT - CHLORIDE TEST KIT -
The TQC Bresle Kit - Chloride Test Kit complies with the ISO 8502-6 and ISO 8502-9 standards that describe the Bresle Method to assess the level of soluble salts using a patch, distilled water and a conductivity gauge. The conductivity is mainly directly proportional to the concentration of dissolved chloride ions in the solution. The kit includes all the necessary equipment to execute a bresle test that will indicate the contamination of soluble salts on blast-cleaned surfaces prior to coating. Inside the TQC Bresle Kit - Chloride Test Kit is a conductivity gauge used for the assessment of soluble salt ions as chlorides, sulphates and nitrates. Contamination of blast-media The TQC Bresle Kit - Chloride Test Kit is also suitable to determine the contamination of blast-media in use. This important test described in the ISO 11127-6 and ISO 11127-7 standards helps to prevent that the dissolved salts in the recycled abrasive media or water will not re-contaminate the surface being cleaned.
Bresle-kit.com  ~   Site Info   Whois   Trace Route   RBL Check  
cocomcabling.com Titus Systems - Voice/Data, Broadband, Fiber Optics, Fire & Security Solutions
Titus Systems has over 20 years in voice/data, fiber optics, broadband, fire & security solutions. Titus Systems is a customer-driven,quality conscious company committed to delivering the best product & service possible. We deliver on time every time
Cocomcabling.com  ~   Site Info   Whois   Trace Route   RBL Check  
Similar Sites: titus-systems.com
sevenstars-jp.com 株式会社七星社
七星社はTQM、TQC、シックスシグマ及びコアツール、統計的分析手法の導入と維持・運用、ISO認証取得およびJIS認証、プライバシー・マークの認証取得支援と維持・運用、ESCO事業、ECO商品の導入サポート、翻訳・通訳・英文文書作成サポートいたします。
Sevenstars-jp.com  ~   Site Info   Whois   Trace Route   RBL Check  
grindometer.com GRINDOMETERS | FINENESS OF GRIND GAUGES -
The TQC Grindometers or Fineness of Grind Gauges are precision instruments to determine particle size and fineness of many materials like paints, lacquers, pigments, filler, chocolate etc.. Most TQC Grindometers have double grooves with graded slopes graduated in three different parameters: µm (microns), NS (Hegman) and PCU (North). Gauge and beveled scraper are made of hardened stainless steel and have an accuracy of 2 µm. Complies with: ASTM D 1210, ASTM D 1316, JIS K 5600-2-5, ISO 1524, DIN EN 21524, BS 3900-C6 Dimensions: The base: 175x60x12mm with 120mm groove length The scraper: 75x38x8mm shaped to be hold easily.
Grindometer.com  ~   Site Info   Whois   Trace Route   RBL Check  
tqcireland.com TQC Ltd. - Ireland - PC Based Industrial Computers, Panel PC, Embedded PC, Industrial Workstation
Industrial PC Systems, Cards & Peripherals for Test, Measurement, Automation & Communication
Tqcireland.com  ~   Site Info   Whois   Trace Route   RBL Check  
baker-applicator.com BAKER APPLICATORS -
Cylindrical film applicator with 4 application sides for applicating paint-films of 4 different pre-defined thicknesses. The Baker applicator’s are available in film width 60 mm and 80 mm and are suitable for applying a host of different products onto flat and relatively solid substrates. Since it’s made out of high-grade stainless steel, the Baker Film Applicator will not be affected by acid or base elements.
Baker-applicator.com  ~   Site Info   Whois   Trace Route   RBL Check  
bird-applicator.com BIRD APPLICATORS -
TQC Prismatic Bird film applicator with flat edges. Four application sides for applying 4 different pre-defined thicknesses. The TQC Bird applicator is available in film width 50, 75 and 100mm and suitable for applying a host of different products onto flat and relatively solid substrates. The high-grade stainless steel will not be affected by acid or base elements. We can give no guarantee of the wet thickness that will be obtained. The wet thickness is dependent upon the solids and vehicle content of the wet material as well as other factors. Film thickness deposited may vary from 40% to 80% of the actual gate clearance of the TQC Bird applicator.
Bird-applicator.com  ~   Site Info   Whois   Trace Route   RBL Check  
totalqualitycorp.com Total Quality Corporation ~ Nationwide Provider of Temporary X-Ray Inspection Systems
Total Quality Corp provides manufacturers product contaminate inspection services, inspection equipment rentals and the sale and training of inspection systems.
Totalqualitycorp.com  ~   Site Info   Whois   Trace Route   RBL Check  
sdxinyatejixie.com ػе޹˾
ػе޹˾
Sdxinyatejixie.com  ~   Site Info   Whois   Trace Route   RBL Check  
bresle-method.com BRESLE METHOD -
The bresle method according the ISO 8502-6 standard describes a method of extraction of soluble contaminants from a surface by means of adhesive TQC Bresle Patches which can be attached to any surface, regardless of its shape and orientation. Suitable for use in field analysis before application of paints. NEW! Bresle Method - TQC Direct Sample Procedure (DSP) TQC developed a new bresle sample method the
Bresle-method.com  ~   Site Info   Whois   Trace Route   RBL Check  
 


Page 3/15« Previous12345Next »
  IP Index    TLD Index    Domain Index    Site Index      Copyright © 2013 dawhois.com